Jump to content

Search the Community

Showing results for tags 'silence'.



More search options

  • Search By Tags

    Type tags separated by commas.
  • Search By Author

Content Type


Forums

  • MSPGeek
    • Announcements
    • The Geek Cast
  • ConnectWise Automate / Labtech
    • ConnectWise Automate / LabTech
    • ConnectWise Automate / LabTech - Development

Categories

  • ConnectWise Automate
    • Scripts
    • Plugins
    • SQL Snippets
    • Role Definitions
    • Automate PowerShell Code
    • Reports
    • Internal Monitors
    • Remote Monitors
  • ConnectWise Manage
    • API Interacting Code

Find results in...

Find results that contain...


Date Created

  • Start

    End


Last Updated

  • Start

    End


Filter by number of...

Joined

  • Start

    End


Group


Location


Agent Count


INTERESTS


OCCUPATION


ICQ


WEBSITE


WLM


YAHOO


AOL


FACEBOOK


GOOGLEPLUS


SKYPE


TWITTER


YOUTUBE

Found 1 result

  1. Hi All, First time posting so please be nice . I've recently configured some HP Hardware monitoring (thanks Joe.McCall !) and now am getting alerts for some systems which is great. I now need to configure the following: 1. Drive failure should alert within 5 minutes. The remote monitor is set to run every 5 minutes, and is continuous.This takes care of this requirement but introduces an issue with ticket alerts being generated continuously. Changing the monitor to 'once' would fix this but would introduce another issue which I am trying to solve (below) 2. The ticket should re-open once daily if the issue is still present. This would 'protect' us if a tech closed the ticket without the issue being resolved. Technically I can address the above by creating two monitors, but then this would create two tickets for each alert. As an alternative, I could 'silence' the alerts for a period of time, perhaps 24 hours by default? I'm not sure how to do this, but coming from a Zabbix/Nagios background, I assume this is pretty simple? I would like to be able to do this anyway, or at least create an exception because another issue I have with the hardware alerts is that some will always fail. We have some HP servers with non-genuine memory and HP SNMP will report this as a failure. Without removing the server from the search group the SNMP checks are applied to, how can I create an exception? It looks like exceptions are only possible with Internal Monitors and not Remote Monitors? Any assistance would be greatly appreciated. Thank you!
×